ACiQ 2 Ton Inverter Heat Pump and Gas Furnace System ACIQ-24-EHPB Hybrid 15.4 SEER2 High Efficiency 80% AFUE 66000 BTU Multi-Positional 14" Width Coil
ID: 089670
ID: 089670
The Inverter Condenser utilizes advanced technology to adjust its compressor speed based on demand by converting AC power to DC, ensuring efficient operation across varying weather conditions. Equipped with a Learning System and sensors for monitoring air temperature, system performance, and more, it optimizes efficiency from the outset and adapts dynamically to heating and cooling needs. The Next Gen 2-ton heat pump system operates like a 1-ton unit in summer, maintaining comfort while managing humidity effectively.
Brand |
ACiQ |
Model # | ACiQ-24-EHPB |
Refrigerant Charge | 25' | Weight | 109.13 |
AHRI Certificate Number | 212394317 | HSPF2 | 9.2 |
Cooling BTU | 24000 BTU | Heating BTU | 24000 BTU |
Maximum CFM | 1,765 | Decibel Level (dBA) | 60 |
Electric Heat | Heat Pump | Refrigerant | R410A |
SEER | 20 | SEER2 | 17 |
Compressor Type | Rotary | Liquid Line | 3/8" |
Suction Line | 5/8" | Electrical | 208/230V 1 Phase 60 Hz |
Max Breaker Size | 30 Amps | Min. Breaker Size | 19 Amps |
Tonnage | 2 Ton | BTU/Tonnage | 24,000 BTU/2 Ton |
Mini-Split Type | Multi-Positional | Min/Max Outdoor Temp for Heating | 5~75 |
Min/Max Outdoor Temp for Cooling | 5~122 | Zone Compatibility | Single Zone |
Height | 26.5" | Width | 35.04" |
Depth | 13.46" |
Brand | ACiQ | Model # | N80MSN0701412A |
Weight (in lbs) | 114 | AHRI Certificate Number | 213146206 |
Exhaust Flue Requirement | Metal | Replaces | N80ESN0701412A |
Furnace Efficiency / AFUE | 80% | Equivalent | Carrier Equivalent: 58SB0A070E14--12 Tempstar Equivalent: TN80ESN0701412A Bryant Equivalent: 810SA36070E14 |
Heating BTU | 66,000 | Blower Motor | Multi 18-Speed Constant Torque (MCT) ECM Motor |
Drive Type | Direct | Maximum CFM | 1075 |
Motor RPM | 1050 | Horsepower | .33 HP |
Configuration | Upflow/Downflow/Horizontal | Max Breaker Size | 15 Amps |
Connection | 1/2" NPT | Maximum Inlet Pressure | 13.6"wc |
Burner Stages | Single | Ignition Type | Direct Ignition with Silicon Nitride Hot Surface Ignitor |
Fuel Type | Propane, Natural Gas | Certification | AHRI Certified |
Height | 33 1/3" | Width | 14 3/16" |
Depth | 29" |
Brand | ACiQ | Model # | ACIQ-24-ACL-14 |
Weight (in lbs) | 46.5 |
Configuration |
Multi-Positional |
Refrigerant | R410A | Liquid Line | 3/8" |
Suction Line | 3/4" | Tonnage | 2 Ton |
Style | A-Coil | Height | 18" |
Width | 14 1/2" | Depth | 21" |
Warranty Type | Residential | Multi-Family | Commercial |
Standard Warranty | 5 year parts | 5 year parts | 5 year parts |
Registered Warranty | 10 year parts | 10 year parts | 5 year parts |
Warranty Type | Residential | Multi-Family | Commercial |
Standard Warranty | 5 year parts | 5 year parts | 5 year parts |
Registered Warranty | 10 year parts | 10 year parts | 5 year parts |
Warranty Type | Residential | Multi-Family | Commercial |
Standard Warranty | 5 year parts | 5 year parts | 5 year parts |
Registered Warranty | 10 year parts | 10 year parts | 5 year parts |
Specification Sheets
Warranty Information
We are not liable for any injuries, damages, or losses resulting from improper service or installation of our products. While we strive to provide reliable and high-quality HVAC products, any issues arising from improper handling, installation, or maintenance are the sole responsibility of the installer or service provider. Customers are encouraged to engage qualified professionals for installation and servicing to ensure safety and optimal performance. By purchasing and using our products, customers agree to hold The Duct Company harmless from any liability related to improper service or installation. It is essential to follow all manufacturer guidelines, industry standards, and local building codes to mitigate risks and ensure safe operation.
Please note that all installations should be performed by a licensed and experienced HVAC professional. Improper installation may result in equipment malfunction, reduced performance, increased energy consumption, and potential safety hazards.
Furthermore, it is essential to understand that any installation not conducted by a qualified HVAC professional may result in the voiding of warranty coverage. Manufacturers typically require installations to be carried out by certified technicians to uphold warranty terms and conditions.
By choosing to have your HVAC systems installed by a qualified professional, you not only protect your investment but also ensure the optimal performance and safety of your heating, ventilation, and air conditioning systems while maintaining warranty coverage.
In compliance with California's Proposition 65, we are obligated to inform you that some products sold on our website may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
While we prioritize the safety and quality of our products, certain components or materials used in manufacturing may contain trace amounts of chemicals listed under Proposition 65. These chemicals may be present in various forms, including but not limited to coatings, adhesives, plastics, and metals.
It's important to note that the presence of these chemicals does not necessarily indicate any risk of harm when the products are used as intended. However, we encourage you to take all necessary precautions when handling or using our products, especially in accordance with any warnings or instructions provided.
For more information about Proposition 65 and the list of chemicals included, please visit the official website here.