The Goodman 1.5 Ton R32 Split Heat Pump is designed for efficient heating and cooling with its 14.5 SEER2 rating, making it ideal for residential or light commercial applications. With a single-stage, rotary compressor, this 208/240V, 1-phase unit delivers 18,000 Btu/H of heating power. Its SmartShift® technology ensures quiet defrost cycles, while high- and low-pressure switches provide enhanced system protection. Built to last, this unit features a durable galvanized-steel cabinet with a sleek gray powder-coated finish and steel louver coil guard. The compressor crankcase heater, bi-flow filter drier, and suction-line accumulator further improve efficiency and reliability.
Brand | Goodman | Model # | GLZS4BA1810 |
Heating (BTU/h) | 18,000 Btu/H | Cooling (BTU/h) | 18,000 Btu/H |
Refrigerant Type | R-32 | SEER 2 | 15.2 |
Unit Depth | 29 in | Unit Height | 32.5 in |
Unit Width | 29 in | Max Overcurrent Protection | 15 A |
Power Voltage/Phase | 208/230V - 1Ph | Compressor Stages | Single Stage |
Compressor Type | Rotary | Motor Type | PSC |
Liquid Line/Suction Line | ⅜" / ¾" | Decibels | 74 |
Valve Connection Type | Sweat | Refrigerant Charge (oz.) | 70 |
Minimum Circuit Ampacity | 11.2 | Electrical Conduit Size | 1/2" or 3/4" |
Equipment Weight (lbs.) | 150 | Shipping Weight (lbs) | 165 |
Ton | 1.5 |
Elevate your HVAC performance with the AMST Ducted Multi-Position Air Handler. Featuring a nine-speed ECM motor for precise airflow control and a compact 17-9/16 inch cabinet, this unit fits in tight spaces while handling 2.5 to 5 tons efficiently. The integrated TXV expansion valve ensures optimal refrigerant management, enhancing both energy savings and reliability. Ideal for versatile installations, the AMST air handler delivers superior comfort and performance for any residential or light commercial setting.
Certifications: AHRI Certified and ETL Listed for quality assurance.
Brand | Goodman | Model # | AMST30BU1300 |
Refrigerant Type | R-32 | Unit Depth | 21 in |
Unit Height | 53.4375 in | Unit Width | 17.5625 in |
Cooling Capacity Nominal | 30,000 Btu/H | Max Overcurrent Protection | 50/60 A |
Power Phase | 1 Ph | Power Voltage | 208/230 V |
Cased/Uncased | Cased | Energy Source | Electric |
Motor Speed Type | Nine Speed ECM | Unit Weight | 129 lb |
Tonnage | 2.5 |
Warranty Type | Residential | Multi-Family | Commercial |
Standard Warranty | 5 year parts | 5 year parts | 5 year parts |
Registered Warranty | 10 year parts | 10 year parts | 5 year parts |
Warranty Type | Residential | Multi-Family | Commercial |
Standard Warranty | 5 year parts | 5 year parts | 5 year parts |
Registered Warranty | 10 year parts | 10 year parts | 5 year parts |
We are not liable for any injuries, damages, or losses resulting from improper service or installation of our products. While we strive to provide reliable and high-quality HVAC products, any issues arising from improper handling, installation, or maintenance are the sole responsibility of the installer or service provider. Customers are encouraged to engage qualified professionals for installation and servicing to ensure safety and optimal performance. By purchasing and using our products, customers agree to hold The Duct Company harmless from any liability related to improper service or installation. It is essential to follow all manufacturer guidelines, industry standards, and local building codes to mitigate risks and ensure safe operation.
Please note that all installations should be performed by a licensed and experienced HVAC professional. Improper installation may result in equipment malfunction, reduced performance, increased energy consumption, and potential safety hazards.
Furthermore, it is essential to understand that any installation not conducted by a qualified HVAC professional may result in the voiding of warranty coverage. Manufacturers typically require installations to be carried out by certified technicians to uphold warranty terms and conditions.
By choosing to have your HVAC systems installed by a qualified professional, you not only protect your investment but also ensure the optimal performance and safety of your heating, ventilation, and air conditioning systems while maintaining warranty coverage.
In compliance with California's Proposition 65, we are obligated to inform you that some products sold on our website may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
While we prioritize the safety and quality of our products, certain components or materials used in manufacturing may contain trace amounts of chemicals listed under Proposition 65. These chemicals may be present in various forms, including but not limited to coatings, adhesives, plastics, and metals.
It's important to note that the presence of these chemicals does not necessarily indicate any risk of harm when the products are used as intended. However, we encourage you to take all necessary precautions when handling or using our products, especially in accordance with any warnings or instructions provided.
For more information about Proposition 65 and the list of chemicals included, please visit the official website here.