Goodman 4 Ton R32 Heat Pump & Air Handler 15.2 SEER2 48K BTU Multi Position
ID: 100777
ID: 100777
Goodman 4 Ton R32 Split Heat Pump GLZS4BA4810 - Energy Efficient Comfort
Discover the Goodman 4 Ton R32 Split Heat Pump (Model GLZS4BA4810), featuring a remarkable 15.2 SEER2 and HSPF rating. With a nominal heating capacity of 48,000 BTU/H, this single-stage scroll compressor unit is designed for optimal performance and energy savings. Key features include SmartShift® Technology for quiet defrosting, enhanced aluminum fin coils for improved heat exchange, and a factory-installed bi-flow liquid-line filter drier. Weighing 269 lb, this durable heat pump is AHRI Certified, ETL Listed, and compliant with Florida Building Code standards. Upgrade your heating and cooling system today!
Brand | Goodman | Model # | GLZS4BA4810 |
Heating (BTU/h) | 48,000 Btu/H | Cooling (BTU/h) | 48,000 Btu/H |
Refrigerant Type | R-32 | SEER 2 | 14.5 |
Unit Depth | 35.5 in | Unit Height | 36.5 in |
Unit Width | 35.5 in | Max Overcurrent Protection | 40 A |
Power Voltage/Phase | 208/230V - 1Ph | Compressor Stages | Single Stage |
Compressor Type | Scroll | Motor Type | PSC |
Liquid Line/Suction Line | ⅜" / 1⅛" | Decibels | 74 |
Valve Connection Type | Sweat | Refrigerant Charge (oz.) | 174 |
Minimum Circuit Ampacity | 25.5 A | Electrical Conduit Size | 1/2" or 3/4" |
Equipment Weight (lbs.) | 269 | Shipping Weight (lbs) | 284 |
Ton | 4 |
The Goodman 4 Ton R32 Ducted Multi-Position Air Handler (AMST48CU1300) offers efficient cooling with a 48,000 BTU/h nominal capacity and features a nine-speed ECM motor for quiet, adaptable airflow. Equipped with an all-aluminum coil for superior heat transfer and optional rust-resistant nickel chromium heating elements (5–10 kW), this unit ensures reliable performance. The unit's SmartFrame cabinet, easy-to-access service points, and multiple installation configurations provide flexibility and durability. Factory-installed components like the pull-type disconnect and thermoplastic drain pan ensure easy setup and maintenance, while its AHRI and ETL certifications confirm quality and safety compliance.
Brand | Goodman | Model # | AMST48CU1300 |
Refrigerant Type | R-32 | Unit Depth | 21 in |
Unit Height | 58 in | Unit Width | 21.125 in |
Cooling Capacity Nominal | 48000 Btu/H | Max Overcurrent Protection | 60/60 A |
Power Phase | 1 Ph | Power Voltage | 208/230 V |
Cased/Uncased | Cased | Energy Source | Electric |
Motor Speed Type | Nine Speed ECM | Unit Weight | 153 lb |
Tonnage | 4 |
Warranty Type | Residential | Multi-Family | Commercial |
Standard Warranty | 5 year parts | 5 year parts | 5 year parts |
Registered Warranty | 10 year parts | 10 year parts | 5 year parts |
Warranty Type | Residential | Multi-Family | Commercial |
Standard Warranty | 5 year parts | 5 year parts | 5 year parts |
Registered Warranty | 10 year parts | 10 year parts | 5 year parts |
We are not liable for any injuries, damages, or losses resulting from improper service or installation of our products. While we strive to provide reliable and high-quality HVAC products, any issues arising from improper handling, installation, or maintenance are the sole responsibility of the installer or service provider. Customers are encouraged to engage qualified professionals for installation and servicing to ensure safety and optimal performance. By purchasing and using our products, customers agree to hold The Duct Company harmless from any liability related to improper service or installation. It is essential to follow all manufacturer guidelines, industry standards, and local building codes to mitigate risks and ensure safe operation.
Please note that all installations should be performed by a licensed and experienced HVAC professional. Improper installation may result in equipment malfunction, reduced performance, increased energy consumption, and potential safety hazards.
Furthermore, it is essential to understand that any installation not conducted by a qualified HVAC professional may result in the voiding of warranty coverage. Manufacturers typically require installations to be carried out by certified technicians to uphold warranty terms and conditions.
By choosing to have your HVAC systems installed by a qualified professional, you not only protect your investment but also ensure the optimal performance and safety of your heating, ventilation, and air conditioning systems while maintaining warranty coverage.
In compliance with California's Proposition 65, we are obligated to inform you that some products sold on our website may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
While we prioritize the safety and quality of our products, certain components or materials used in manufacturing may contain trace amounts of chemicals listed under Proposition 65. These chemicals may be present in various forms, including but not limited to coatings, adhesives, plastics, and metals.
It's important to note that the presence of these chemicals does not necessarily indicate any risk of harm when the products are used as intended. However, we encourage you to take all necessary precautions when handling or using our products, especially in accordance with any warnings or instructions provided.
For more information about Proposition 65 and the list of chemicals included, please visit the official website here.