Skip to content
Autumn Sale | Enjoy Better Savings! Add to Cart For Best Pricing & Take Advantage of No Sales Tax In Most States
Autumn Sale | Enjoy Better Savings! Add to Cart For Best Pricing & Take Advantage of No Sales Tax In Most States

Goodman R32 80% AFUE Gas Furnace 100K BTU 21" Wide 2-Stage Upflow/Horizontal

by Goodman
SKU GR9T801004CN

ID: 100965

Thumbs Up Icon FREE Shipping (5-7 Business Days)

Thumbs Up Icon No Sales Tax (Excludes CA)

Thumbs Up Icon Satisfaction or Return within 30 Days

Thumbs Up Icon Need Help? Call: (833) 658-3387

Original price $1,435.00 - Original price $1,435.00
Original price
$1,435.00
$1,435.00 - $1,435.00
Current price $1,435.00

Shipping Icon FREE SHIPPING

ADD TO CART FOR BEST PRICE

Your Webpage

Why Buy From Us:

Product Accessories

DESCRIPTION


The Goodman 80% AFUE R32 2-Stage Gas Furnace provides 100,000 BTU of efficient, quiet heating with a multi-speed ECM circulator motor and two-stage gas valve for optimal comfort. Equipped with a SureStart® Silicon Nitride igniter for long life, it operates smoothly with a low constant fan speed and quiet, two-speed draft blower. The furnace features a self-diagnostic control board, is AHRI Certified and ETL Listed for quality, and meets California Low NOx emissions standards. With flexible installation options and a durable, insulated cabinet, it ensures reliable home heating and easy setup.

  • Unit Height: 33-3/8 in
  • Unit Width: 21 in
  • AFUE: 80 %
  • 100,000 BTU 
  • 1600 CFM
  • Installation Configuration: Upflow/Horizontal
  • Max Overcurrent Protection: 20 A
  • Power Phase: 1 Ph
  • Power Voltage: 115 V
  • Motor Speed Type: Nine Speed ECM
  • Unit Weight: 124 lb
  • Model Efficiency: 0.8
  • Unit Depth: 28 in
  • Heat Exchanger Type: Air Cooled
  • NOx: > 40 NG/J NOx

Product Features For Goodman 80% AFUE R32 2-Stage Gas Furnace

  • Two-stage gas valve provides quiet, economical heating
  • Efficient and quiet multi-speed ECM circulator motor
  • SureStart® Silicon Nitride igniter designed for long igniter life
  • Self-diagnostic control board
  • Low constant fan speed circulates air throughout the home
  • Quiet, two-speed induced draft blower
  • California Low NOx emissions-compliant models available
  • Not for installation in California's South Coast Air Quality Management District (SCAQMD) and San Joaquin Valley Air Pollution Control District (SJVAPCD)
  • AHRI Certified and ETL Listed for quality assurance

Cabinet Features

  • Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
  • Multi-position installation:
    • GR9T80: Upflow, horizontal left or right
    • GD9T80: Downflow, horizontal left or right
  • Removable bottom for side- or bottom-return applications
  • Convenient left or right gas/electric service connections
  • Cabinet air leakage ≤ 2%
  • Coil and furnace fit flush for most installations
Brand Goodman SKU GR9T801004CN
Type Gas Heat Category Gas Furnaces
Refrigerant Type R-32 AHRI Certificate Number 215358032
Airflow Direction Upflow/Horizontal Exhaust Flue Requirement Metal
Replaces GM9C801004CN, GMEC801004CN Product Features New Refrigerant Compliant
Furnace Efficiency / AFUE 80% Heating BTU 100,000
LP/Natural Gas BTU Output 80,000 Temperature Rise Range (°F) 25-55
Blower Motor 9 Speed - ECM Maximum CFM 1600
Configuration Upflow/Horizontal Electrical 115v 1 Phase 60 Hz
Horsepower - RPM 3/4 HP Max Breaker Size 20 Amps
Min. Breaker Size 11.3 Amps Burner Stages Two
Fuel Type Propane, Natural Gas Height 33 3/8"
Width 21" Depth 28"
No. of Burners 5 UPC 633190210555
Shipping Weight 124

WARRANTY COVERAGE

Warranty Type Residential Multi-Family Commercial
Standard Warranty 5 year parts 5 year parts 5 year parts
Registered Warranty 10 year parts 10 year parts 5 year parts

PRODUCT DOCUMENTS & TECHNICAL SPECIFICATIONS



GR9T80 / GD9T80 Specification Sheets 

GR9T80 / GD9T80 Installation Manual

GR9T80 / GD9T80 Warranty Information

PRODUCT INFORMATION DISCLAIMERS

Safety Liability Notice

We are not liable for any injuries, damages, or losses resulting from improper service or installation of our products. While we strive to provide reliable and high-quality HVAC products, any issues arising from improper handling, installation, or maintenance are the sole responsibility of the installer or service provider. Customers are encouraged to engage qualified professionals for installation and servicing to ensure safety and optimal performance. By purchasing and using our products, customers agree to hold The Duct Company harmless from any liability related to improper service or installation. It is essential to follow all manufacturer guidelines, industry standards, and local building codes to mitigate risks and ensure safe operation.

Installation Disclaimer

Please note that all installations should be performed by a licensed and experienced HVAC professional. Improper installation may result in equipment malfunction, reduced performance, increased energy consumption, and potential safety hazards.

Furthermore, it is essential to understand that any installation not conducted by a qualified HVAC professional may result in the voiding of warranty coverage. Manufacturers typically require installations to be carried out by certified technicians to uphold warranty terms and conditions.

By choosing to have your HVAC systems installed by a qualified professional, you not only protect your investment but also ensure the optimal performance and safety of your heating, ventilation, and air conditioning systems while maintaining warranty coverage.

California Prop 65 Warning

In compliance with California's Proposition 65, we are obligated to inform you that some products sold on our website may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

While we prioritize the safety and quality of our products, certain components or materials used in manufacturing may contain trace amounts of chemicals listed under Proposition 65. These chemicals may be present in various forms, including but not limited to coatings, adhesives, plastics, and metals.

It's important to note that the presence of these chemicals does not necessarily indicate any risk of harm when the products are used as intended. However, we encourage you to take all necessary precautions when handling or using our products, especially in accordance with any warnings or instructions provided.

For more information about Proposition 65 and the list of chemicals included, please visit the official website here.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)